Mustafa Sultan Science & Industry Co. L.L.C.
Critical Care


Laryngeal Mask

LARYNGEAL MASK CO.

CTRACH
The LMA CTrach is designed to increase intubation success rates in difficult airways. The LMA CTrach mask enables ventilation during intubation attempts while built-in fiberoptics provide a direct view of the larynx and real time visualization of the ET tube passing through the vocal cords.

FASTRACH
Designed for anticipated or unanticipated difficult airway situations and for cardiopulmonary resuscitation, the LMA Fastrach facilitates continuous ventilation during intubation, lessening the likelihood of desaturation.

PROSEAL
The added features of the LMA ProSeal include:
  • A softer silicone cuff reducing the likelihood of throat irritation and stimulation
  • High seal pressure - up to 30 cm H20 - Providing a tighter seal against the glottic opening with no increase in mucosal pressure
  • Provides more airway security
  • Enables use of PPV in those cases where it may be required - transient or extended, planned or unplanned
  • A built-in drain tube designed to channel fluid away and permit gastric access for patients with GERD or during extended cases where endotracheal intubation is not required
  • Ability to realize the benefits of spontaneous ventilation more often
  • Optional Insertion tool

E. T. Tubes

Willy Rusch

Patient friendly intubations with a wealth of innovative features.
Quality products needed by today's healthcare professionals.

Tracheostomy Tubes

Tracheostomy tubes from Rusch are available in numerous versions:
with or without Widescope (low-pressure) cuff, with or without phonation window, with adjustable flange. And armoured, e.g. the TracheoFlex tubes, to prevent kinking and compression.

Breathing filters

Filters for all purposes whether bacterial and viral filtration, whether with or without passive humidification: Rusch Arios filters are optimally suited to their various fields of application.

Spinal Needles

Bd Spinal Needle Quincke Type Point
  1. Fine Qunicke bevel (short bevel) : high quality penetration.
  2. High quality steel needle for easy, regular insertion.
  3. accurate alignment of needle and stylet: prevents biopsy effect.
  4. Translucent hub for clearer visualization of CSF
  5. silicon free nos side effects.
  6. Good needle grip and handling.
  7. Biologically safe: controlled sterilsation individually packed in sterile peel-back "blister packs"
Breathing Circuits

The diversity of Rusch anesthesia circuits is convincing. The modular system crates an ideal basis for every kind of application. The individual components are selected by the user, and can then be configured and supplied by RUSCH as a set. For more flexibility and Safety, for greater saving of time and costs.

Blood Gas Analyzer

ABL800 FLEX Automated benchtop analyzer

ABL800 FLEX
Automatic measurement

Ideal for medium- to high-volume testing sites, the ABL800 FLEX measures any combination of pH, blood gas, electrolyte, oximetry and metabolite parameters. This highly accurate analyzer offers many automated features to help you streamline your work process and reduce errors.

Parameters : pH, cH+,
Blood gas : pCO2, pO2,
Electrolytes : cCI-, cCa2+, cK+, cNa+,
Metabolites : cGlu, cLac, cCrea, ctBil,
Oximetry : ctHb, sO2, FO2Hb, FCOHb, FMetHb, FHHb, FHbF

Integrated solution
The ABL800 FLEX is a component of the world's first automatic blood gas system: 1st automatic. Increase testing speed, reduce errors and improve patient and operator safety. All you have to do is sample, scan and go. Specifications Automatically identify, mix and measure samples

 

  • FLEXQ module automatically identifies, mixes and measures up to three samples in succession
  • Automated identification and mixing reduce risk of operator errors
  • Samples are automatically conveyed to the inlet and aspirated into the analyzer, so operators are free to return to their patients
Get lab-quality results at the point of care
  • 128 wavelengths for full CO-oximetry
  • Automatic measurement and suppression of interferences from fetal hemoglobin, bilirubin, intralipids and sulfhemoglobin
  • No interference from Evans Blue and Cadio Green on oximetry results
  • Accurate glucose and lactate measurements
  • Fully automated micromodes ensure accuracy of very small samples
  • FLEXMODE ensures high sample success rate of precious capillary samples by providing the highest number of parameters as reliably possible
Achieve maximum control and efficiency
  • Windows� XP operating system
  • Automatic result processing, test ordering and transmission to the LIS system
  • Automatic data archiving and customizable layout
  • Data backup with read/write CD-ROM drive
  • USB ports for easy connection of e.g. flash drives, keyboards, etc.
  • Hospital network integration through ASTM, HL7 and POCT1A standard communication protocols or via RADIANCE STAT analyzer and data management system
  • The ABL800 FLEX is part of 1st automatic, the world�s first automatic blood gas analysis system
ABL80 FLEX Automated, cartridge-based analyzer

ABL80 FLEX
Portability and fast turnaround time in point-of-care testing

Suitable for POC testing in low-, medium- and high-volume testing sites, the ABL80 FLEX measures pH, blood gas, electrolyte, oximetry and metabolite parameters. This portable, cartridge-based analyzer features fast cycle time and automated QC for maintenance-free operation.

Parameters : pH,
Blood gas : pCO2, pO2,
Electrolytes : cCI-, cCa2+, cK+, cNa+,
Hematocrit : Hct,
Metabolites : cGlu,
Oximetry : ctHb, sO2, FO2Hb, FCOHb, FMetHb, FHHb, Specifications Fast TAT at the point of care
  • 100 seconds from result to result (140 seconds with CO-OX)
  • Start-up time ~8 minutes after change of cassette (20 minutes with CO-OX)
  • Sample volume of only 70 uL of whole blood (105 uL with CO-OX)
Ease of use
  • Customizable user interface
  • Automated entry and logging of consumables enabled via smart chips
  • Simple and fast replacement of consumables
  • Fast and accurate data input with integrated barcode scanner
Automatic quality control
  • Three levels (low, normal, high) of aqueous QC material spanning a broad portion of the reportable range
  • Continual system checks
  • Levey-Jennings plots for easy graphical overview
Full flexibility
  • The small size fits anywhere - footprint only 9 x 11 in (22 x 28 cm)
  • Weighs only 19 lbs (8.5 kg) - carry or move it on a rolling stand
  • Several parameter panels and test volumes make it suitable for a varity of testing sites
  • Fully operational on battery
Connectivity and seamless IT integration
  • Ethernet network connection ensures easy documentation
  • All common communication protocols, including POCT1-A*
  • Data backup with read/write CD drive and USB ports
  • The ABL80 FLEX is part of 1st automatic, the world�s first automatic blood gas analysis system
AutoCheck

Automated QC module
AutoCheck
Eliminate preanalytical errors
  • No person-to-person variation
  • No temperature errors
  • No shaking errors
  • No heating of the ampoule by hand
Save time and improve quality measurements
  • Automated procedures ensure high analyzer uptime
  • Automatic level detection as well as temperature and altitude correction
  • Ability to preprogram quality control schedule at your convenience
  • CV% improved on measurement of pH, pO2 and pCO2 parameters
Advanced surveillance of analyzer performance QUALICHECK+

Quality control ampoules
QUALICHECK+
Check the quality of your analyzer
  • Quality control ampoules are specifically developed for Radiometer's analyzers
  • Different parameter profiles (different combinations of blood gases, oximetry, electrolytes and metabolites)
  • Control ranges based on thorough studies
Simplify quality control with automated procedures
  • Automated procedures ensure high analyzer uptime
  • Automatic level detection (ABL800 FLEX and ABL80 FLEX) and altitude correction (ABL800 FLEX)
  • Automatic temperature correction by using typed-in temperature (ABL800 FLEX and ABL80 FLEX)
Optimize work routines through convenient product storage
  • Most ampoules can be conveniently stored at room temperature
  • Storage tray with built-in thermometer can be ordered
  • 24-months shelf life
Advanced surveillance of analyzer performance IT System RADIANCE STAT analyser and
data management system


RADIANCE
RADIANCE is software designed specifically to meet the traditional needs of data management systems (DMS) and to enhance them with functions for the management of STAT analyser systems.

The RADIANCE software offers a flexible and simple connectivity solution for both STAT analysers and hospital and laboratory information systems (HIS & LIS).
Collect and store patient, QC, calibration and system data
  • Report data according to local QA requirements, available on demand for paperless regulatory inspections
  • Manually or automatically process patient data, including addition of accession number
  • Sophisticated data handling assists correct identification of patient results on Radiometer ABL analysers
Remotely monitor and control Radiometer analysers
  • Monitor analyser status
  • Perform troubleshooting
  • Confirm analytical accuracy with AutoCheck QC
Save time
  • Remote control of Radiometer analyzers
  • Automated accession numbering
  • Secure access from anywhere to users from within or from outside the hospital network system
Reduce workload, improve productivity
  • Automated completion of maintenance log for Radiometer analyzers
  • Combined maintenance log and to-do reminder system for all analyzers
  • Report manager prompts users to review reports and provides electronic logging of review process
  • RADIANCE connects most brands of POC STAT analyzers. Protocols supported include ASTM, HL7 and POCT1-A
Improve patient care
  • Real-time monitoring and remote control maximize analyzer uptime
  • 100 % data capture through continuous data synchronization between analyzers and RADIANCE and the LIS
  • 100 % data accuracy - on-screen verification feature provides the
    ABL analyzer user with the capability to correctly identify the correct patient
FLEXLINK

The FLEXLINK software links sampler, patient and operator IDs at the bedside, making data readily available to caregivers and eliminating the risk of incorrect patient identification. FLEXLINK is a PC- and PDA-compatible RADIANCE software module.
QA Portal

The web-based service, the QA Portal, helps you collect, process, report and archive QA data from your blood gas analysers placed throughout the hospital. FLEXLINK Secure data capture at the bedside

FLEXLINK
The FLEXLINK scans and links sampler, patient and operator IDs at the bedside, making data readily available to caregivers and eliminating the risk of incorrect patient identification. The information is stored by FLEXLINK. Ensure correct sample and patient identification
  • Once the prebarcoded sampler is placed in the analyzer, the analyzer recognizes the sampler and automatically retrieves the correct patient information from FLEXLINK matching it with the test result.
Get results where needed
  • FLEXLINK makes the correctly identified results available immediately to caregivers on the LIS, PDAs, PCs, patient monitors or wherever required
Customize FLEXLINK to your needs
  • FLEXLINK is a PC- and PDA-compatible RADIANCE software module
  • Because it is user-definable, FLEXLINK can be customized to match the process workflow of your hospital
Integrated solution

The FLEXLINK is part of the world's first automatic blood gas system: 1st automatic. All you have to do is sample, scan and go. Samplers safePICO Safety-engineered ABG sampler

safePICO
Reduce the risk of needle-stick injuries
  • Integrated one-hand-operation device allows safe removal of needles
Quickly remove air bubbles and avoid contact with patient blood
  • The safeTIPCAP simplifies the removal of air bubbles
  • Once air bubbles have been expelled, the sample is sealed for anaerobic transport
  • The risk of contact with patient blood is limited
Ensure fast and proper mixing with integrated mixing device
  • The integrated metal ball works as a mixing device, ensuring correct and fast mixing of the sample prior to analysis
Correctly identify samples with safePICO's unique barcode ID
  • safePICO is prebarcoded making it easy to identify samples correctly
Features

Explore the safePICO animation to learn about the features of the sampler. Integrated solution

The safePICO is a component of the world's first automatic blood gas system: 1st automatic. All you have to do is sample, scan and go. PICO70 Self-fill arterial sampler

PICO70
Minimize patient discomfort
  • Sharp needles ensure smooth arterial penetration
  • Super thin needle technology of smaller-sized needles secure faster filling and optimal blood flow
Avoid test biases and clots
  • Unique plunger vent mechanism and air channels in the preattached tip cap prevent pO2 biases
  • High concentration of Radiometer's dry, electrolyte-balanced heparin (60 IU per mL) prevents clotting
  • Preheparinized to avoid sample dilution errors
Avoid preanalytical errors

Radiometer's pocket-sized "The whole-blood sampling handbook" gives you information on sampling techniques to help avoid preanalytical errors.

CLINITUBES Glass or "non-PVC"
plastic capillary tubes


CLINITUBE
Match different analyzer requirements
  • Variety of sizes to match sample-volume requirements of individual analyzers
Draw blood samples quickly, easily and safely
  • Unique surface treatment ensures fast filling of plastic capillary tubes
  • Mixing wires provide optimal mixing of the sample minimizing the risk of clotting
  • Plastic capillary samplers eliminate risk of breakage, staff injury and contamination
Secure sample quality
  • Uniform heparin coating ensures homogeneous sample quality
  • Glass capillary samplers secure airtight storage and reliable pO2 results
  • High concentration of Radiometer's electrolyte-balanced heparin ensures reliable results
  • Clot catchers can be used as an extra precaution to avoid clotting
Avoid preanalytical errors

Radiometer's pocket-sized The whole-blood sampling handbook or Avoiding preanalytical errors in capillary blood gas testing gives you information on sampling techniques to help avoid preanalytical errors.

safePICO Mixer

Automated sample mixing

Ensure a thorough and uniform mixing from sample to sample by using the safePICO Mixer.
    • Mixes a sample in just 7 seconds
    • Thorough and uniform mixing ensures sample integrity
    • Aspiration through vented safeTIPCAP
    • Automated mixing reduces preanalytical errors and saves time
Transcutaneous Monitor

Transcutaneous Monitoring TCM4/40 Simultaneous ventilation and oxygen status measurement
TCM4/40

Simplicity, accuracy, portability The TCM4 serie's transcutaneous monitor is used to evaluate the respiratory status of critically ill patients as well as those suffering from sleep disorders.

The monitor measures SpO2, tcpO2 and tcpCO2; parameters can be measured together or separately. The TCM4 series is lightweight and portable, highly accurate and simple to use.

TCM4 Parameters

Transcutaneous oxygen tension: tcpO2
Transcutaneous carbon dioxide tension : tcpCO2

Specifications
TCM4/40

Detect patient changes immediately

 

  • The TCM4 provides transcutaneous pO2 and pCO2 information continuously and non-invasively
  • SmartHeat function stabilizes transcutaneous values faster
  • Unique electrode technology provides accurate and rapid measurements
  • SmartTrend ensures stable measurements, reflecting actual physiological changes in patient status
Windows CE� and touch screen technology make it easy to use
  • Always ready due to SmartCal integrated automatic calibration
  • Complete overview of patient history with trend curves
  • Windows platform allows easy integration with other systems
Take it everywhere
  • Lightweight
  • Flexible handle
  • Built-in battery
TCM40
TCM4/40

Parameters

Transcutaneous oxygen tension: tcpO2
Transcutaneous carbon dioxide tension : tcpCO2
Oxygen saturation : SpO2,

Specifications

Measure SpO2 together with tcpO2/tcpCO2
  • Two separate sensors provide continuous measurement of tcpO2/tcpCO2 and SpO2
  • Combined tcpO2/tcpCO2 or single tcpCO2 sensors
  • Compatibility with all Nellcor sensors
  • Get values fast
SmartHeat rapidly stabilizes transcutaneous values
  • SmartTrend provides values reflecting actual changes in patient status
  • Unique electrode technology ensures accurate and rapid measurements
  • Use it right away
Windows CE and touch screen technology make it easy to use
  • Always ready due to SmartCal integrated automatic calibration
  • Complete overview of patient history with trend curves
  • Windows platform allows easy integration with other systems
Take it everywhere
  • Lightweight
  • Flexible handle
  • Built-in battery
TCM400 Precise assessment
of cutaneous oxygenation

TCM400

Six measurements, one instrument

The TCM400 is used in wound care and hyperbarics, where transcutaneous measurements are an effective diagnostic tool in the detection and treatment of critical limb ischemia.


Highly accurate and easy to use, the TCM400 is the first and only portable instrument to provide up to six simultaneous measurements of transcutaneous oxygen tension (tcpO2).

Self-guided demonstration

Explore the TCM400 animation to learn about the features of the analyzer.

Explore the TC animation to learn about the different measuring principles.

Parameters

Transcutaneous oxygen tension: tcpO2
Electrode heating : Power

Calculated Regional Perfusion Index : RPI Specifications Get detailed information when assessing cutaneous oxygenation
  • TCM400 provides up to six simultaneous measurements of transcutaneous oxygen tension (tcpO2)
  • Monitor can be customized by choosing the number (1-6) of measuring modules
Optimize your work routine
  • Color touch screen and the user-friendly Windows CE software make the TCM400 easy and intuitive to operate
  • Patient information is automatically linked to measurements
  • Patient name and ID can easily be inserted using the on-screen keyboard
  • Predefined textual event can be inserted during measurements
  • Monitor's built-in battery, light weight and compact design allow it to be easily transported
Document your measurements
    • Trends can be displayed and printed in both graphical and tabular formats
    • Reports can also be printed, removing the risk of human errors associated with handwritten reports

Nasopharyngeal airway made of PVC

  • Transparent
  • Sterile
Blood Glucose Monitors

SD CHECK GOLD

 

  • GOLD ELECTRODE
  • LASER PATTERNING
  • 0.9ul blood sample volume
  • Code Chip Calibration

(Auto-adjusts to temperature change)
(Test Strip expiration date checking)

  • Fast 5-Seconds Test
  • 400 Memory and Indexing
  • 7, 14, 30-Day Averaging
  • 10,000 Times Measurement
  • Full automation manufacturing line

Product Composition

  • Blood Glucose meter
  • Blood Glucose test strip
  • Lancing device
  • Lancets
  • Code chip
  • Carrying case
  • Battery
  • Check strip
  • Self test diary
  • User guide
  • Control solution

Product Features

Assay method Glucose oxidase biosensor
Test result range 10~600 mg/dL (0.6 ~ 33.3 mmol/L)
Test time 5 Seconds
Test blood volume 0.9ul
Blood reference type Whole blood reference or Plasma reference
Glucose unit mg/dL, mmol/L
Memory 400 blood glucose results
Functions Averaging: 7, 14, 30-day specific averages Automatic shutoff
Size Meter 44(W) x 92(H) x 18(D) mm
Test strip 5.5(W) x 30(H) x 0.53(D) mm
Weight 50g
Battery 3V Battery type CR2032
Battery life time 10,000 test for continuously operation
Test Strip Shelf-life 18 months




Contact Email:

 