Mustafa Sultan Science & Industry Co. L.L.C.
Neurology
EEG

Comet XL Lab-based EEG - Recording & Review

Comet XL is a complete EEG system designed to satisfy the needs of the physician's office, hospital, or medical center. Ready to use, Comet XL is supplied with the latest high performance PC and Photic Stimulator. Select from various mobile carts, cabinets and monitor sizes to suit your individual needs.

These powerful, easy-to-use EEG systems consist of the high response 50-channel AS40 Amplifier System, a Personality Module with electrode inputs designed especially for EEG, and TWin EEG Record and Review Software. These flexible systems upgrade easily to also record PSG studies. Powerful Panorama digital video and TWin Companion EKG Holter software options are available.

See printers and video monitoring equipment for information. FEATURES
  • Compact design that is rugged, lightweight, and easy to use
  • On-board analog to digital conversion for interference-free recordings
  • Easily connect to any PC with the on-board Ethernet connection
  • Flexible enough for both EEG and PSG applications
  • 40 AC channels and optional 8 DC channels
  • Optional pulse oximeter for SpO2 and rate
  • Easy, identifiable electrode input with the International 10-20 placement layout
  • On-board impedance checking, calibrations, and photic control at the amplifier system
  • Easily mounted next to a patient bed or attached to a cart for mobile EEG tests
  • Limited Lifetime Warranty on Grass Technologies manufactured parts
Amplifier System - reliable, state-of-the-art

Grass Technologies amplifiers are world-renowned in the field of neurophysiology for their quality, reliability, simplicity, and serviceability. At the heart of the Comet EEG system is the AS40 Amplifier System. The amplifier system is designed specifically for the EEG and PSG monitoring lab and combines the latest digital design techniques with years of amplifier design and manufacturing experience.

The AS40 is a compact 40-channel AC amplifier unit. An optional 8-channel DC input module and optional pulse oximeter allow for an additional 10 channels of data. This flexibility allows for wide range of physiological parameters to be monitored and recorded.

The amplifier system provides for patient safety isolation, signal conditioning (physiological signal amplification and filtering), and digitization. Communications with a host computer are accomplished using TCP/IP protocol over a 10BaseT Ethernet network or dedicated cable. A host computer, using TWin software, sets the sample rate, starts and stops the data transmission, monitors the digital data, and stores it to hard disk.

An intuitive user interface with LCD screen is present with the amplifier. From the amplifier itself, a user is able to implement such features as electrode impedance checking, amplifier calibration, and photic stimulator control. Also from the LCD display a user is able to obtain information such as connection status to the host computer, and oximetry/pulse rate information when an oximeter is in use.

Personality Modules The flexible design of the amplifier allows different Personality Modules to be used. A patented concept*, the Personality Module communicates with the TWin software for setup and configuration of the system. The UPM Universal Personality Module is supplied with the amplifier in Comet EEG systems.

The UPM has 32 referential EEG inputs, 1 reference input, 1 patient ground and 8 bipolar AC channels for a total of 40 channels. An optional SPM, Sleep Personality Module, is also available.

The Personality Module's design allows for an easy disconnect/reconnect to the amplifier system. Direct-connect and tethered versions of the personality modules are available

Comet XL EEG with optional IT9 mobile rack cart and 18" flat-panel monitor



Universal Polarity Module, optional Sleep Personality Module and DC Input Module Beehive Horizon - Long-term Epilepsy Monitoring
The Beehive Horizon is the next generation of recorders in the ubiquitous Beehive Long-term Monitoring product line. Decades of experience in designing and manufacturing reliable, high-quality epilepsy monitoring instrumentation combined with the latest technology has produced a powerful Windows-based digital EEG/Video instrument with complete data acquisition, recording and review capabilities that are specialized for epilepsy monitoring applications.

SYSTEM FEATURES
  • Compact design that is rugged, lightweight, and easy to use
  • On-board analog to digital conversion for artifact-free recordings
  • Built-in Grass designed and developed SzAC automatic seizure/spike analysis
  • Built-in Panorama digital video with highly-efficient Grass Technologies MPEG4 compression for 640 x 480 NTSC (768 x 576 PAL) resolution
  • On-board impedance checking, calibrations, and photic control at the amplifier system
  • Quick disconnect cable
  • Limited Lifetime Warranty on Grass Technologies manufactured parts (see our full warranty for details)
40-Channel Base System:
The 40-channel EEG/LTM system consists of the high response, 32-channel, patient-worn AURA  Amplifier System with tethered Base Station and 8-input DC Module. A Patient Event Marker pushbutton is provided.

64-Channel Expanded System:
The 64-channel EEG/LTM system consists of of the high response, patient-worn AURA-LTM64 Amplifier System with tethered Base Station. The amplifier has 68 inputs (64 channels, 2 reference, 2 isolated ground).

128-Channel Expanded System:
Two AURA-LTM64 amplifier units are connected with an amplifier-to-amplifier interconnect cable to provide 128 EEG channel acquisition.

Grass Technologies amplifiers are world-renowned in the field of neurophysiology for their quality, reliability, simplicity, and serviceability.

The amplifier system provides for patient safety isolation, signal conditioning (physiological signal amplification and filtering), and digitization. Communications with a host computer are accomplished using TCP/IP protocol over an Ethernet network or dedicated cable. A host computer, using TWin software, sets the sample rate, starts and stops the data transmission, monitors the digital data, and stores it to hard disk or an optional file server.

AURA 32-CHANNEL AMPLIFIER SYSTEM
AURA (Ambulatory Universal Recording Amplifier) amplifier system has a front-end sampling rate of 400 Hz (record 200 or 400 Hz, user definable). The electrode input jack box provides 32 AC inputs, 2 reference inputs and 2 ground inputs. The redundant references and grounds provide reliability and signal integrity during long-term monitoring procedures.

The 32-channel system has the capability of recording data directly to a PC or can be untethered for temporary ambulatory recordings. The compact and lightweight design of AURA offers maximum patient comfort, without sacrificing the ruggedness required for long-term studies.

AURA is typically tethered to the base station, which streams data to a host computer running TWin. However, AURA is also capable of operating untethered. When untethered, AURA will run off of an internal battery and save data to a CompactFlash  (CF) memory card. AURA is capable of over 2 hours of untethered recording. If there is an immediate need to download and review the data stored on the CompactFlash memory card, the CF can be removed from AURA and the data can be downloaded quickly via a USB CompactFlash Reader.

With AURA, the patient can travel from their patient room to a day room. When the patient arrives at the day room, AURA simply needs to be plugged into any base station located in that room. Our TWin recording software will recognize that the patient has switched to a new base station, and tethered recording will resume again. An optional external battery pack is available to enable recording of 24-hour ambulatory EEG studies.

An 8-channel DC input module and optional pulse oximeter (SpO2/HR) allow for an additional 10 channels of data. This flexibility allows for wide range of physiological parameters to be monitored and recorded.

An intuitive user interface with LCD screen is present with the base station. From the base station itself, the technologist is able to implement such features as electrode impedance checking, amplifier calibration, and photic stimulator control. Also from the LCD display it is possible to obtain information such as connection status to the host computer, and oximetry/pulse rate information if an oximeter is in use.

AURA-LTM64 64 - and 128 - CHANNEL AMPLIFIER SYSTEM
The AURA-LTM64 amplifier, with integrated electrode input connections, is designed for use either as a bedside amplifier or as a wearable cabled-telemetry amplifier unit which allows the patient to have greater freedom of movement within their patient room. Provided accessories include a patient-worn pouch and 33-foot (10 m) patient cable. The integrated electrode input connections provides 64 AC inputs, 2 reference electrode inputs, and 2 ground inputs. Two amplifiers are connected for 128-channel recordings using a single link cable between them. Jack box adhesive labels are provided for labeling the inputs with international 10-20 and 1-64 numerical nomenclature, 10-10 nomenclature, and/or 65-128 nomenclature. The AURA-LTM64 64/128 amplifiers are modular and can be used with multiple recording systems.

When used for scalp recording, the amplifiers built-in electrode impedance meter can be activated via software from the recording PC, or by pressing the impedance button on the amplifier. The electrode connector inputs exceeding the user-defined impedance value will light up, making it easy for the technologists to identify which electrodes need attention. When used for invasive electrode recordings, the built-in impedance meter is disabled.

AURA-LTM64 amplifier systems maximum possible sample rate is 3200 samples per second (64 channels) with a maximum possible bandwidth up to 1000 Hz *. Auxiliary inputs are also available for connecting a Patient Event Push Button and an optional photic stimulator.

* Frequency response is approximately 1/3 of the front end sampling rate. The sampling rate and the storage rate is set by TWin software and available sampling rates are dependent on the TWin software version.

Software & Options:
Easy-to-use Grass Technologies TWin LTM software is provided along with Archive Manager, and TWinLOOK software. SzAC Automatic Spike Seizure Analysis software for proven on-line event recognition is also included. Intuitive editing tools streamline the process of identifying EEG/Video events for further analysis and archiving.

Grass Technologies Panorama Digital Video/Audio recording system, is included. Choose from a variety of camera options. Beehive Horizon offers the widest range of accessories and options designed specifically for the epilepsy monitoring unit, including Nurse Alarm Systems, Pager Systems, TWin Companion EKG Holter software, Grass Patient Scheduler software, TWin Monitor 2 software and more. Neurotrac III Neuromonitoring Software is also available.




EMG
Alpine has long been the recognized innovator of neurodiagnostic systems. The newest addition to the Keypoint Family is Keypoint .NET which combines the esteemed Amplifiers and Stimulators from Keypoint with leading edge software technology to improve the way diagnostic studies are performed - whether in a hospital, clinic, office or surgical ward.

Utilizing the .NET technology, we designed what we believe is the most intuitive and easy-to-use EMG/EP system available today. Keypoint .NET gives you more accuracy and a faster workflow, tailored to the way you prefer to work and with just one click way.

3 Configurations:



Keypoint Workstation
The Keypoint Workstation provides you with a number of options that can be adapted to the individual situation and patient. Standard Keypoint features now include flat screen, integrated CD-ROM writer, and ergonomic hand rest.

Hardware Configuration:
Comes as either a 2, 4 or 8-channel with single or dual current stimulator. Built - in auditory or visual stimulator.
















Keypoint Portable

The Keypoint Portable is so compact in size it fits in a handy carrying case or trolley. But that does not mean it compromises on performance features.

Hardware Configuration:
Comes as a 2-channel with built - in single current stimulator. Built-in auditory or visual stimulator.

Keypoint Portable

The Keypoint  Portable is so compact in size it fits in a handy carrying case or trolley. But that does not mean it compromises on performance features.

Hardware Configuration:
Comes as a 2 - channel with built-in single current stimulator. Built - in auditory or visual stimulator.















Keypoint 4

Keypoint 4 is an economical 4-channel EMG, NCS and EP system for fast and reliable neurodiagnostic results. Small in size and easy to operate, the Keypoint 4 is the ideal product for both clinics and private medical office settings, where either connectivity or portability is important.

Hardware Configuration: Comes as a 4 - channel with single or dual current stimulator. Built-in auditory or visual stimulator.

Applications
With Keypoint applications, you do not need to buy excess performance capabilities.

PSG
Comet XL Lab - based PSG - Recording & Review
Comet XL is a complete PSG system designed to satisfy the needs of the physician's office, hospital, or medical center. Ready to use, Comet XL is supplied with the latest high performance PC. A DC Input Module is included for up to 8 channels. Select from various mobile carts, cabinets and monitor sizes to suit your individual needs.

These powerful, easy-to-use PSG systems consist of the high response 50-channel AS40 Amplifier System, a Personality Module with electrode inputs designed especially for PSG, and TWin PSG Record and Review Software. These flexible systems upgrade easily to also record EEG studies. Grass's powerful Panorama digital video option, FASS Fully-Automated Sleep Stager, TWin Companion EKG Holter software and a wide selection of supplies and accessories are also available

FEATURES:
  • Compact design that is rugged, lightweight, and easy to use
  • On-board analog to digital conversion for interference-free recordings
  • Easily connect to any PC with the onboard Ethernet connection
  • Flexible enough for both EEG and PSG applications
  • Up to 50 total available channels
  • Integrated pulse-oximeter connection providing SpO2 and heart rate
  • Easy, identifiable electrode input with the head and body diagram layout
  • Onboard impedance checking and calibrations at the amplifier system
  • Easily mounted next to a patient bed or attached to a cart
  • Limited Lifetime Warranty on Grass Technologies manufactured parts


Neuroradiology

Allura Xper FD20 / 10



Biplane X-ray system offers exceptional insight for interventional neuroradiology examinations.
New insight with advanced biplane neuro X-ray system. Exceptional insight for challenging neurovascular interventions is yours with the Philips Allura Xper FD20/10 biplane neuro X-ray system. It combines superb flat detector image quality with advanced interventional tools to give you a clear view of vessel morphology. So you can be more confident of making the right decisions. It is the ideal system for an interventional neuro suite.

Allura Xper FD20 / 20



Philips Allura Xper FD20/20 biplane neuro X-ray system offers excellent insight for challenging diagnostic examinations and neurovascular interventions. It features two large flat detectors with Philips 2k imaging and advanced interventional tools to give you a clear view of vessel morphology. The support you need to be more confident of making the right decisions.